Lsc · Lsc Smart Connect Lsc Indoor Ptz Camera · CVE-2025-25680
Name of the Vulnerable Software and Affected Versions:
LSC Smart Connect LSC Indoor PTZ Camera version 7.6.32
Description:
The issue concerns a remote code execution (RCE) vulnerability in the `tuya ipc direct connect` function of the `anyka ipc` process. This vulnerability allows for arbitrary code execution through the Wi-Fi configuration process when a specially crafted QR code is presented to the camera.
Recommendations:
For LSC Smart Connect LSC Indoor PTZ Camera version 7.6.32, as a temporary workaround, consider disabling the `tuya ipc direct connect` function until a patch is available. Restrict access to the Wi-Fi configuration process to minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability.