PT-2007-5688 · Sophos · Sophos Anti-Virus For Windows
Publicado
2007-09-10
·
Atualizado
2018-10-15
·
CVE-2007-4512
CVSS v2.0
4.3
Média
| Vetor | AV:N/AC:M/Au:N/C:N/I:P/A:N |
Name of the Vulnerable Software and Affected Versions
Sophos Anti-Virus for Windows versions 6.x through 6.5.7
Sophos Anti-Virus for Windows versions 7.x through 7.0.0
Description
The issue allows remote attackers to inject arbitrary web script or HTML via an archive with a file that matches a virus signature and has a crafted filename. This is due to the filename not being properly handled by the print function in SavMain.exe.
Recommendations
For Sophos Anti-Virus for Windows versions 6.x through 6.5.7, update to version 6.5.8 or later.
For Sophos Anti-Virus for Windows versions 7.x through 7.0.0, update to version 7.0.1 or later.
Correção
XSS
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾
Enumeração de Fraquezas
Identificadores relacionados
Produtos afetados
Sophos Anti-Virus For Windows