PT-2009-1164 · Hewlett Packard · Hp Mercury Quality Center
Publicado
2009-02-24
·
Atualizado
2018-10-15
·
CVE-2007-5289
CVSS v2.0
7.6
Alta
| Vetor | AV:N/AC:H/Au:N/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
HP Mercury Quality Center (QC) versions 9.2 and earlier
Description
The issue allows remote attackers to execute arbitrary code via crafted use of the Open Test Architecture (OTA) API. This is achieved by modifying certain files, such as
common.tds, defects.tds, manrun.tds, req.tds, testlab.tds, or testplan.tds, in the %tmp%TD 80 directory, and then setting the file's properties to read-only.Recommendations
For HP Mercury Quality Center (QC) versions 9.2 and earlier, consider restricting access to the Open Test Architecture (OTA) API until a patch is available. As a temporary workaround, avoid using the OTA API for critical operations and limit user capabilities to minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾
Enumeração de Fraquezas
Identificadores relacionados
Produtos afetados
Hp Mercury Quality Center