PT-2011-3120 · Emc · Emc Sourceone Email Management
Publicado
2011-05-24
·
Atualizado
2018-10-09
·
CVE-2011-1424
CVSS v2.0
3.5
Baixa
| Vetor | AV:N/AC:M/Au:S/C:P/I:N/A:N |
Name of the Vulnerable Software and Affected Versions
EMC SourceOne Email Management versions prior to 6.6 SP1
Description
The issue arises from the default configuration of ExShortcutWeb.config in EMC SourceOne Email Management, specifically when the Mobile Services component is utilized. The localOnly attribute of the trace element is not properly set, allowing remote authenticated users to obtain sensitive information via ASP.NET Application Tracing.
Recommendations
For versions prior to 6.6 SP1, update to version 6.6 SP1 or later to resolve the issue. As a temporary workaround, consider setting the localOnly attribute of the trace element to true in the ExShortcutWeb.config file to restrict access to ASP.NET Application Tracing.
Correção
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾
Enumeração de Fraquezas
Identificadores relacionados
Produtos afetados
Emc Sourceone Email Management