PT-2013-5115 · Siemens · Scalance W7Xx
Publicado
2013-07-31
·
Atualizado
2013-08-01
·
CVE-2013-4651
CVSS v2.0
6.6
Média
| Vetor | AV:N/AC:H/Au:N/C:P/I:P/A:C |
Name of the Vulnerable Software and Affected Versions
Siemens Scalance W7xx devices with firmware prior to 4.5.4
Description
The issue allows remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging a hardcoded X.509 certificate's trust relationship. This is because the same certificate is used across different customers' installations.
Recommendations
For Siemens Scalance W7xx devices with firmware prior to 4.5.4, update the firmware to version 4.5.4 or later to resolve the issue.
Correção
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾
Enumeração de Fraquezas
Identificadores relacionados
Produtos afetados
Scalance W7Xx