PT-2014-1002 · Siemens · Simatic S7-1200 Cpu

Publicado

2014-03-20

·

Atualizado

2020-02-10

·

CVE-2014-2256

CVSS v2.0

7.8

Alta

VetorAV:N/AC:L/Au:N/C:N/I:N/A:C
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU PLC devices with firmware prior to 4.0
Description The issue allows remote attackers to cause a denial of service, resulting in a defect-mode transition, via crafted ISO-TSAP packets. Exploitation can be achieved by sending a special TCP/IP packet to port 102, which can cause the device to transition into an emergency mode that lasts until a hardware reset is performed.
Recommendations For Siemens SIMATIC S7-1200 CPU PLC devices with firmware prior to 4.0, update the firmware to version 4.0 or later to resolve the issue.

Correção

Improper Resource Release

Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾

Enumeração de Fraquezas

Identificadores relacionados

BDU:2014-00020
CVE-2014-2256

Produtos afetados

Simatic S7-1200 Cpu