PT-2018-13497 · Tenda · Tenda Ac9+1

Publicado

2018-09-02

·

Atualizado

2018-10-25

·

CVE-2018-16334

CVSS v2.0

9.0

Alta

VetorAV:N/AC:L/Au:S/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions Tenda AC9 version 15.03.05.19(6318) CN Tenda AC10 version 15.03.06.23 CN
Description An issue was discovered where the mac parameter in a POST request is used directly in a doSystemCmd call, causing OS command injection.
Recommendations For Tenda AC9 version 15.03.05.19(6318) CN, avoid using the mac parameter in the affected API endpoint until the issue is resolved. For Tenda AC10 version 15.03.06.23 CN, avoid using the mac parameter in the affected API endpoint until the issue is resolved. As a temporary workaround, consider restricting access to the doSystemCmd call to minimize the risk of exploitation.

Exploit

Correção

OS Command Injection

Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾

Enumeração de Fraquezas

Identificadores relacionados

CVE-2018-16334

Produtos afetados

Tenda Ac10
Tenda Ac9