PT-2018-18773 · Iobit · Advanced Systemcare Ultimate

Publicado

2018-03-25

·

Atualizado

2018-03-30

·

CVE-2018-9003

CVSS v3.1

7.8

Alta

VetorAV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions Advanced SystemCare Ultimate version 11.0.1.58
Description The issue is related to the driver file Monitor x86.sys, which does not validate input values from IOCtl 0x9c402000. This can allow local users to cause a denial of service (BSOD) or possibly have other unspecified impacts.
Recommendations For Advanced SystemCare Ultimate version 11.0.1.58, consider updating to a newer version that addresses this issue, as the current version allows for potential denial of service or other impacts due to the lack of input validation in the Monitor x86.sys driver file. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Exploit

RCE

Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾

Enumeração de Fraquezas

Identificadores relacionados

CVE-2018-9003

Produtos afetados

Advanced Systemcare Ultimate