PT-2018-2194 · Siemens · Sinumerik 828D+1

Publicado

2018-12-11

·

Atualizado

2019-10-09

·

CVE-2018-11458

CVSS v2.0

10

Alta

VetorAV:N/AC:L/Au:N/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions SINUMERIK 828D V4.7 versions prior to V4.7 SP6 HF1 SINUMERIK 840D sl V4.7 versions prior to V4.7 SP6 HF5 SINUMERIK 840D sl V4.8 versions prior to V4.8 SP3
Description The issue is related to an integer overflow in the VNC server of the affected products. Exploitation of this issue could allow a remote attacker to execute arbitrary code with privileged permissions by sending specially crafted network requests to port 5900/tcp. This can be done without any privileges or user interaction, potentially compromising the confidentiality, integrity, and availability of the VNC server. The vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration.
Recommendations For SINUMERIK 828D V4.7 versions prior to V4.7 SP6 HF1, update to V4.7 SP6 HF1 or later. For SINUMERIK 840D sl V4.7 versions prior to V4.7 SP6 HF5, update to V4.7 SP6 HF5 or later. For SINUMERIK 840D sl V4.8 versions prior to V4.8 SP3, update to V4.8 SP3 or later. As a temporary workaround, consider restricting access to port 5900/tcp to minimize the risk of exploitation.

Correção

Integer Overflow

Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾

Enumeração de Fraquezas

Identificadores relacionados

BDU:2019-00172
CVE-2018-11458

Produtos afetados

Sinumerik 828D
Sinumerik 840D Sl