Name of the Vulnerable Software and Affected Versions Seiko Solutions SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier Seiko Solutions SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
Description A missing authentication issue for a critical function exists in the Seiko Solutions SkyBridge series, allowing a remote attacker to obtain or alter the product's setting information or execute critical functions without authentication, such as rebooting the product.
Recommendations For Seiko Solutions SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, update to a version later than Ver. 01.00.05 to resolve the issue. For Seiko Solutions SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, update to a version later than Ver. 1.4.1 to resolve the issue. As a temporary workaround, consider restricting access to critical functions that do not require authentication until a patch is available.