PT-2023-21995 · Siemens · Simatic Cloud Connect 7 Cc716+1
CVE-2023-28832
·
Publicado
2023-05-09
·
Atualizado
2023-05-15
CVSS v3.1
7.2
Alta
| Vetor | AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H |
Name of the Vulnerable Software and Affected Versions
SIMATIC Cloud Connect 7 CC712 versions 2.0 through 2.1
SIMATIC Cloud Connect 7 CC716 versions 2.0 through 2.1
Description
A vulnerability has been identified where the web-based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Recommendations
For SIMATIC Cloud Connect 7 CC712 versions 2.0 through 2.1, update to a version outside of this range to mitigate the risk.
For SIMATIC Cloud Connect 7 CC716 versions 2.0 through 2.1, update to a version outside of this range to mitigate the risk.
As a temporary workaround, consider restricting access to the web-based management interface until a patch is available.
Correção
Command Injection
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾
Enumeração de Fraquezas
Identificadores relacionados
Produtos afetados
Simatic Cloud Connect 7 Cc712
Simatic Cloud Connect 7 Cc716