PT-2023-25541 · Diebold Nixdorf · Diebold Nixdorf Vynamic View Console

CVE-2023-36344

·

Publicado

2023-08-08

·

Atualizado

2023-08-14

CVSS v3.1

7.8

Alta

VetorAV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions Diebold Nixdorf Vynamic View Console versions 5.3.1 and earlier
Description The issue allows a local attacker to execute arbitrary code via not restricting the search path for required DLLs and not verifying the signature. This enables the attacker to potentially exploit the system.
Recommendations For Diebold Nixdorf Vynamic View Console versions 5.3.1 and earlier, restrict the search path for required DLLs and verify the signature to prevent arbitrary code execution. As a temporary workaround, consider restricting access to the console to minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Uncontrolled Search Path Element