PT-2023-4072 · Siemens · Tecnomatix Plant Simulation
CVE-2023-37374
·
Publicado
2023-05-23
·
Atualizado
2023-10-19
CVSS v3.1
7.8
Alta
| Vetor | AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
Name of the Vulnerable Software and Affected Versions
Tecnomatix Plant Simulation versions prior to V2201.0008
Tecnomatix Plant Simulation versions prior to V2302.0002
Description
The issue is related to a stack-based buffer overflow in the affected application when parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. The vulnerability is associated with the processing of STP files, which can lead to the execution of arbitrary code.
Recommendations
For versions prior to V2201.0008, update to version V2201.0008 or later.
For versions prior to V2302.0002, update to version V2302.0002 or later.
As a temporary workaround, consider restricting the processing of STP files until a patch is available. Avoid using the affected application to parse specially crafted STP files until the issue is resolved.
Correção
Stack Overflow
Memory Corruption
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾
Identificadores relacionados
Produtos afetados