PT-2023-6602 · Nextgen Healthcare · Mirth Connect

Naveen Sunkavally

·

Publicado

2023-06-21

·

Atualizado

2026-05-31

·

CVE-2023-43208

CVSS v3.1

10

Crítica

VetorAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions NextGen Healthcare Mirth Connect versions prior to 4.4.1
Description The issue is related to an incomplete patch for a previous vulnerability, leading to unauthenticated remote code execution. This vulnerability is caused by insufficient access control in the Mirth Connect web server, allowing an attacker to execute arbitrary code remotely. The vulnerability is related to insecure usage of the Java XStream library for unmarshalling XML payloads. It has been reported that this vulnerability is being actively exploited, and it poses a significant risk to healthcare companies using the Mirth Connect platform.
Recommendations Update to version 4.4.1 or later to prevent unauthorized access. As a temporary workaround, consider restricting access to the Mirth Connect administrator interface until a patch is applied.

Exploit

Correção

RCE

OS Command Injection

Improper Privilege Management

Improper Access Control

Command Injection

Deserialization of Untrusted Data

Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾

Identificadores relacionados

BDU:2023-07369
BDU:2024-05267
CVE-2023-43208

Produtos afetados

Mirth Connect