PT-2023-7123 · Siemens · Sinema Server

CVE-2023-35796

·

Publicado

2023-10-10

·

Atualizado

2023-11-14

CVSS v2.0

10

Crítica

VetorAV:N/AC:L/Au:N/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions SINEMA Server V14 (All versions)
Description A vulnerability has been identified in the SINEMA Server application, where it improperly sanitizes certain SNMP configuration data retrieved from monitored devices. This could allow an attacker with access to a monitored device to perform a stored cross-site scripting (XSS) attack, potentially leading to arbitrary code execution with SYSTEM privileges on the application server.
Recommendations For SINEMA Server V14 (All versions), consider restricting access to monitored devices and SNMP configuration data to minimize the risk of exploitation. As a temporary workaround, disabling the SNMP configuration data retrieval feature may help mitigate the issue until a patch is available. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

XSS

Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾

Enumeração de Fraquezas

Identificadores relacionados

BDU:2023-08150
CVE-2023-35796
ZDI-23-1600

Produtos afetados

Sinema Server