PT-1998-1201 · Us Robotics/3Com · Us Robotics/3Com Total Control Chassis With Frame Relay

Published

1998-05-11

·

Updated

2016-10-18

·

CVE-1999-1389

CVSS v2.0

7.5

High

VectorAV:N/AC:L/Au:N/C:P/I:P/A:P
Name of the Vulnerable Software and Affected Versions US Robotics/3Com Total Control Chassis with Frame Relay versions 3.6.22 through 3.7.24
Description The issue concerns the improper enforcement of access filters when a specific setting is applied. Attackers can bypass restrictions by providing the hostname twice at the "host: " prompt.
Recommendations For versions 3.6.22 through 3.7.24, consider disabling the "set host prompt" setting for all ports to prevent attackers from bypassing access filters. Restrict access to the "host: " prompt to minimize the risk of exploitation.

Fix

Found an issue in the description? Have something to add? Feel free to write us 👾

Related Identifiers

CVE-1999-1389

Affected Products

Us Robotics/3Com Total Control Chassis With Frame Relay