PT-2007-7094 · Hewlett Packard · Hp Openview Network Node Manager
Muts
·
Published
2007-12-13
·
Updated
2018-10-15
·
CVE-2007-6204
CVSS v2.0
10
High
| Vector | AV:N/AC:L/Au:N/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
HP OpenView Network Node Manager versions 6.41 through 7.51
Description
The issue is related to multiple stack-based buffer overflows that allow remote attackers to execute arbitrary code. This can be achieved by providing long arguments to certain executables, such as
ovlogin.exe, OpenView5.exe, snmpviewer.exe, and webappmon.exe. For example, a long Action parameter to OpenView5.exe can be used to demonstrate this issue.Recommendations
For HP OpenView Network Node Manager versions 6.41 through 7.51, consider disabling the executables
ovlogin.exe, OpenView5.exe, snmpviewer.exe, and webappmon.exe until a patch is available to prevent remote attackers from executing arbitrary code.
At the moment, there is no information about a newer version that contains a fix for this vulnerability.Exploit
Buffer Overflow
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Hp Openview Network Node Manager