PT-2007-7115 · Apc · Apc Ap7932

Published

2007-12-04

·

Updated

2018-10-15

·

CVE-2007-6226

CVSS v2.0

7.1

High

VectorAV:N/AC:M/Au:N/C:N/I:N/A:C
Name of the Vulnerable Software and Affected Versions APC AP7932 0u 30amp Switched Rack Power Distribution Unit (PDU) with rpdu version 3.5.5 and aos version 3.5.6
Description The issue allows remote attackers to bypass authentication and obtain login access by making a login attempt while a different client is logged in, and then resubmitting the login attempt once the other client exits.
Recommendations For APC AP7932 0u 30amp Switched Rack Power Distribution Unit (PDU) with rpdu version 3.5.5 and aos version 3.5.6, consider temporarily restricting access to the login functionality until a patch is available. As a mitigation measure, restrict concurrent login attempts to minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Improper Authentication

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2007-6226

Affected Products

Apc Ap7932