PT-2008-3241 · Hewlett Packard · Hp Openview Network Node Manager
Muts
·
Published
2008-04-08
·
Updated
2017-09-29
·
CVE-2008-1697
CVSS v2.0
10
High
| Vector | AV:N/AC:L/Au:N/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
HP OpenView Network Node Manager versions 7.53, 7.51, and earlier
Description
The issue is related to a stack-based buffer overflow in the ovwparser.dll module of HP OpenView Network Node Manager. This can be exploited by remote attackers who send a long URI in an HTTP request processed by ovas.exe, potentially allowing the execution of arbitrary code. An example of such an exploit is a certain topology/homeBaseView request.
Recommendations
For HP OpenView Network Node Manager versions 7.53 and 7.51, update to a version later than 7.53 to resolve the issue.
For HP OpenView Network Node Manager versions earlier than 7.51, update to a version later than 7.53 to resolve the issue.
As a temporary workaround, consider restricting access to the ovas.exe module and the ovwparser.dll file to minimize the risk of exploitation.
Exploit
Fix
Buffer Overflow
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Hp Openview Network Node Manager