PT-2010-2431 · Hyleos · Hyleos Chemview
Dz_Attacker
·
Published
2010-02-22
·
Updated
2010-02-23
·
CVE-2010-0679
CVSS v2.0
9.3
High
| Vector | AV:N/AC:M/Au:N/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
Hyleos ChemView version 1.9.5.1
Description
The issue concerns multiple stack-based buffer overflows in the HyleosChemView.HLChemView ActiveX control. This occurs when a large number of white space characters are included in the filename argument to the SaveasMolFile and ReadMolFile methods, allowing remote attackers to execute arbitrary code.
Recommendations
For Hyleos ChemView version 1.9.5.1, consider disabling the SaveasMolFile and ReadMolFile methods until a patch is available to prevent potential exploitation. Restrict access to the HyleosChemView.HLChemView ActiveX control to minimize the risk of arbitrary code execution. Avoid using the filename argument with a large number of white space characters in the affected methods. At the moment, there is no information about a newer version that contains a fix for this issue.
Exploit
Fix
Buffer Overflow
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Hyleos Chemview