PT-2012-1797 · Siemens · Tecnomatix Factorylink
Published
2012-01-08
·
Updated
2017-08-29
·
CVE-2011-4055
CVSS v2.0
9.3
High
| Vector | AV:N/AC:M/Au:N/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
Siemens Tecnomatix FactoryLink versions 6.6.1 through 8.0.2.54
Description
The issue is related to a buffer overflow in the WebClient ActiveX control. This can be exploited by remote attackers to execute arbitrary code via a long string in a parameter associated with the location URL.
Recommendations
For versions 6.6.1, 7.5.217, and 8.0.2.54, consider disabling the WebClient ActiveX control as a temporary workaround until a patch is available. Restrict access to the location URL parameter to minimize the risk of exploitation.
Fix
Buffer Overflow
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Tecnomatix Factorylink