PT-2012-2421 · Ge Intelligent Platforms · Proficy Plant Applications
Published
2012-03-15
·
Updated
2018-01-11
·
CVE-2012-0230
CVSS v2.0
10
High
| Vector | AV:N/AC:L/Au:N/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
GE Intelligent Platforms Proficy Plant Applications versions 5.0 and earlier
Description
The issue allows remote attackers to cause a denial of service or possibly execute arbitrary code via a crafted TCP session on port 12299. This is due to a problem in PRRDS.exe within the Proficy Remote Data Service.
Recommendations
For versions 5.0 and earlier, consider restricting access to port 12299 to minimize the risk of exploitation. As a temporary workaround, limiting the use of the Proficy Remote Data Service may help mitigate the issue. At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Buffer Overflow
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Proficy Plant Applications