PT-2013-5334 · National Instruments · Labwindows/Cvi+1
Published
2013-08-06
·
Updated
2013-09-25
·
CVE-2013-5023
CVSS v2.0
4.3
Medium
| Vector | AV:N/AC:M/Au:N/C:N/I:N/A:P |
Name of the Vulnerable Software and Affected Versions
National Instruments LabWindows/CVI versions 2012 SP1 and earlier
National Instruments LabVIEW versions 2012 SP1 and earlier
Description
The issue allows remote attackers to cause a denial of service by triggering the display of local .chm files through the ActiveX controls in the HelpAsst component in NI Help Links.
Recommendations
For National Instruments LabWindows/CVI versions 2012 SP1 and earlier, consider disabling the ActiveX controls in the HelpAsst component as a temporary workaround until a patch is available.
For National Instruments LabVIEW versions 2012 SP1 and earlier, consider disabling the ActiveX controls in the HelpAsst component as a temporary workaround until a patch is available.
At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Found an issue in the description? Have something to add? Feel free to write us 👾
Related Identifiers
Affected Products
Labview
Labwindows/Cvi