PT-2014-1220 · Siemens · Simatic Wincc
Published
2014-02-06
·
Updated
2017-08-29
·
CVE-2014-1699
CVSS v2.0
5.0
Medium
| Vector | AV:N/AC:L/Au:N/C:N/I:N/A:P |
Name of the Vulnerable Software and Affected Versions
Siemens SIMATIC WinCC OA versions prior to 3.12 P002 January
Description
The issue allows remote attackers to cause a denial of service, specifically a monitoring-service outage, via malformed HTTP requests to port 4999. This can be exploited by sending specially crafted TCP packets, enabling an attacker to disrupt the monitoring service without needing to authenticate.
Recommendations
For versions prior to 3.12 P002 January, update to version 3.12 P002 January or later to resolve the issue. As a temporary workaround, consider restricting access to port 4999 to minimize the risk of exploitation.