PT-2015-4047 · Siemens · Scalance X 408+1

Published

2015-01-21

·

Updated

2020-02-10

·

CVE-2014-8479

CVSS v2.0

6.8

Medium

VectorAV:N/AC:L/Au:S/C:N/I:N/A:C
Name of the Vulnerable Software and Affected Versions Siemens SCALANCE X-300 switches versions prior to 4.0 Siemens SCALANCE X 408 switches versions prior to 4.0
Description The issue allows remote authenticated users to cause a denial of service, resulting in a reboot of the system, by sending crafted FTP packets to the FTP server.
Recommendations For Siemens SCALANCE X-300 switches with firmware prior to 4.0, update to version 4.0 or later. For Siemens SCALANCE X 408 switches with firmware prior to 4.0, update to version 4.0 or later.

Fix

RCE

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2014-8479

Affected Products

Scalance X 408
Scalance X-300