PT-2015-7806 · Schneider Electric · Proclima

Ariele Caltabiano

+1

·

Published

2015-12-08

·

Updated

2015-12-16

·

CVE-2015-8561

CVSS v2.0

6.8

Medium

VectorAV:N/AC:M/Au:N/C:P/I:P/A:P
Name of the Vulnerable Software and Affected Versions Schneider Electric ProClima versions prior to 6.2
Description The issue allows remote attackers to execute arbitrary code or cause a denial of service due to memory corruption. This can be achieved by providing a crafted integer value to certain methods in the F1BookView ActiveX control, including the AttachToSS, CopyAll, CopyRange, CopyRangeEx, or SwapTable method.
Recommendations For versions prior to 6.2, update to version 6.2 or later to resolve the issue. As a temporary workaround, consider disabling the AttachToSS, CopyAll, CopyRange, CopyRangeEx, and SwapTable methods in the F1BookView ActiveX control until a patch is available.

Fix

Buffer Overflow

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2015-8561
ZDI-15-626
ZDI-15-627
ZDI-15-628
ZDI-15-629

Affected Products

Proclima