PT-2016-4679 · Juniper Networks · Junos

Published

2016-09-09

·

Updated

2017-09-01

·

CVE-2016-1275

CVSS v3.1

6.5

Medium

VectorAV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Name of the Vulnerable Software and Affected Versions Juniper Junos OS versions prior to 13.3R9 Juniper Junos OS versions 14.1R6 before 14.1R6-S1 Juniper Junos OS versions 14.1 before 14.1R7
Description The issue allows remote attackers to obtain sensitive mbuf information by injecting a flood of Ethernet frames with IPv6 MAC addresses directly into a connected interface, when configured with VPLS routing-instances.
Recommendations For Juniper Junos OS versions prior to 13.3R9, update to version 13.3R9 or later. For Juniper Junos OS versions 14.1R6 before 14.1R6-S1, update to version 14.1R6-S1 or later. For Juniper Junos OS versions 14.1 before 14.1R7, update to version 14.1R7 or later.

Fix

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2016-1275

Affected Products

Junos