PT-2017-16580 · Eclinicalworks · Eclinicalworks Patient Portal

Published

2017-01-23

·

Updated

2017-01-26

·

CVE-2017-5569

CVSS v3.1

9.8

Critical

VectorAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions eClinicalWorks Patient Portal version 7.0 build 13
Description An issue was discovered that allows for blind SQL injection within the template.jsp file. This can be exploited without authentication via an HTTP POST request. The issue can be used to dump database data to a malicious server using out-of-band techniques such as select loadfile().
Recommendations For eClinicalWorks Patient Portal version 7.0 build 13, consider restricting access to the template.jsp file until a patch is available. As a temporary workaround, avoid using the vulnerable template.jsp file to minimize the risk of exploitation.

Fix

SQL injection

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2017-5569

Affected Products

Eclinicalworks Patient Portal