PT-2017-17601 · Miele Professional · Pst10 Webserver+1
Jens Regel
·
Published
2017-03-24
·
Updated
2017-08-16
·
CVE-2017-7240
CVSS v2.0
5.0
Medium
| Vector | AV:N/AC:L/Au:N/C:P/I:N/A:N |
Name of the Vulnerable Software and Affected Versions
Miele Professional PST10 devices versions 2.02 through 2.12
Miele Professional PST10 devices versions 2.51 through 2.61
Miele Professional PST10 devices versions 2.52 through 2.62
Miele Professional PST10 devices versions 2.54 through 2.64
Miele Professional PST10 devices versions 1.00 through 1.10
Miele Professional PST10 devices versions 1.04 through 1.14
Miele Professional PST10 devices versions 1.10 through 1.20
Miele Professional PST10 devices versions 1.14 through 1.24
Description
An issue was discovered in the embedded webserver "PST10 WebServer" of Miele Professional PST10 devices, which is prone to a directory traversal attack. This allows an unauthenticated attacker to access sensitive information, potentially aiding in subsequent attacks. The attack can be exploited by sending a GET request to a specific endpoint, such as "GET /../../../../../../../../../../../../etc/shadow HTTP/1.1".
Recommendations
For versions 2.02 through 2.12, update to version 2.12 or later.
For versions 2.51 through 2.61, update to version 2.61 or later.
For versions 2.52 through 2.62, update to version 2.62 or later.
For versions 2.54 through 2.64, update to version 2.64 or later.
For versions 1.00 through 1.10, update to version 1.10 or later.
For versions 1.04 through 1.14, update to version 1.14 or later.
For versions 1.10 through 1.20, update to version 1.20 or later.
For versions 1.14 through 1.24, update to version 1.24 or later.
Exploit
Fix
Path traversal
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Pst10