PT-2017-3142 · Binom · Binom3 Universal Multifunctional Electric Power Quality Meter
Karn Ganeshen
·
Published
2017-01-31
·
Updated
2017-02-16
·
CVE-2017-5162
CVSS v2.0
10
High
| Vector | AV:N/AC:L/Au:N/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
BINOM3 Universal Multifunctional Electric Power Quality Meter (affected versions not specified)
Description
The issue is related to the lack of authentication for remote services in the BINOM3 Universal Multifunctional Electric Power Quality Meter, which allows unauthorized access to the application setup and configuration. This could enable a remote attacker to gain access to the device and perform arbitrary configuration changes.
Recommendations
At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Exploit
Missing Authentication
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Binom3 Universal Multifunctional Electric Power Quality Meter