PT-2017-3359 · Acti · Acti Cameras

Mandar Jadhav

·

Published

2017-01-20

·

Updated

2019-10-09

·

CVE-2017-3184

CVSS v3.1

10

Critical

VectorAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions ACTi cameras versions A1D-500-V6.11.31-AC
Description The issue is related to inadequate access control in the firmware of ACTi cameras, which can be exploited by a remote attacker. By directly accessing the "http://x.x.x.x/setup/setup maintain firmware-default.html" page, an attacker can perform a factory reset on the device. This can lead to a denial of service condition or allow the attacker to access the device using default credentials.
Recommendations For version A1D-500-V6.11.31-AC, consider restricting access to the factory reset page as a temporary workaround until a patch is available. Avoid using the default credentials in the affected API endpoint until the issue is resolved. As a mitigation measure, restrict access to the setup maintain firmware-default.html page to minimize the risk of exploitation.

Fix

Missing Authentication

Improper Access Control

Using Hardcoded Credentials

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

BDU:2018-00130
CVE-2017-3184

Affected Products

Acti Cameras