PT-2017-3462 · Hewlett Packard · Hpe Intelligent Management Center

Published

2017-08-11

·

Updated

2018-02-23

·

CVE-2017-12515

CVSS v2.0

9.0

High

VectorAV:N/AC:L/Au:S/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions HPE Intelligent Management Center (iMC) PLAT version PLAT 7.3 (E0504)
Description A Remote Code Execution issue was discovered, related to insufficient input validation in the iccSelectRules.xhtml component. This allows a remote attacker to execute arbitrary code using the beanName parameter.
Recommendations For HPE Intelligent Management Center PLAT version PLAT 7.3 (E0504), update to HPE Intelligent Management Center PLAT v7.3 (E0506) or any subsequent version to resolve the issue. As a temporary workaround, consider restricting access to the iccSelectRules.xhtml component to minimize the risk of exploitation.

Fix

RCE

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

BDU:2018-00287
CVE-2017-12515
ZDI-17-680

Affected Products

Hpe Intelligent Management Center