PT-2018-18278 · Schneider Electric · Pelco Sarix Professional

Published

2018-07-03

·

Updated

2019-10-03

·

CVE-2018-7782

CVSS v3.1

8.8

High

VectorAV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions: Schneider Electric Pelco Sarix Professional 1st generation cameras versions prior to 3.29.69
Description: The issue allows authenticated users to view passwords in clear text.
Recommendations: For versions prior to 3.29.69, update the firmware to version 3.29.69 or later to resolve the issue.

Fix

Insufficiently Protected Credentials

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2018-7782

Affected Products

Pelco Sarix Professional