PT-2018-8598 · Cisco · Cisco Industrial Ethernet 4010 Series Switches+1

Published

2018-01-18

·

Updated

2019-10-09

·

CVE-2018-0088

CVSS v2.0

7.2

High

VectorAV:L/AC:L/Au:N/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions: Cisco Industrial Ethernet 4010 Series Switches running Cisco IOS Software (affected versions not specified)
Description: A vulnerability in the diagnostic test CLI commands could allow an authenticated, local attacker to impact the stability of the device, potentially resulting in arbitrary code execution or a denial of service (DoS) condition. The attacker must have valid user credentials at privilege level 15. The issue is due to a diagnostic test CLI command that allows writing to the device memory. An attacker could exploit this by authenticating to the device and issuing a specific diagnostic test command, potentially overwriting system memory locations and negatively impacting the device's stability.
Recommendations: At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Incorrect Permission

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2018-0088

Affected Products

Cisco Ios
Cisco Industrial Ethernet 4010 Series Switches