PT-2019-18147 · Mitsubishi · Mitsubishi Electric Q26Udehcpu+8
Tri Quach
·
Published
2019-02-05
·
Updated
2025-06-26
·
CVE-2019-6535
CVSS v3.1
7.5
High
| Vector | AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
Name of the Vulnerable Software and Affected Versions
Mitsubishi Electric Q03UDVCPU versions serial number 20081 and prior
Mitsubishi Electric Q04UDVCPU versions serial number 20081 and prior
Mitsubishi Electric Q06UDVCPU versions serial number 20081 and prior
Mitsubishi Electric Q13UDVCPU versions serial number 20081 and prior
Mitsubishi Electric Q26UDVCPU versions serial number 20081 and prior
Mitsubishi Electric Q03UDECPU versions serial number 20101 and prior
Mitsubishi Electric Q04UDEHCPU versions serial number 20101 and prior
Mitsubishi Electric Q06UDEHCPU versions serial number 20101 and prior
Mitsubishi Electric Q10UDEHCPU versions serial number 20101 and prior
Mitsubishi Electric Q13UDEHCPU versions serial number 20101 and prior
Mitsubishi Electric Q20UDEHCPU versions serial number 20101 and prior
Mitsubishi Electric Q26UDEHCPU versions serial number 20101 and prior
Mitsubishi Electric Q50UDEHCPU versions serial number 20101 and prior
Mitsubishi Electric Q100UDEHCPU versions serial number 20101 and prior
Description
A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash.
Recommendations
For Mitsubishi Electric Q03UDVCPU versions serial number 20081 and prior, update to a version with a serial number later than 20081.
For Mitsubishi Electric Q04UDVCPU versions serial number 20081 and prior, update to a version with a serial number later than 20081.
For Mitsubishi Electric Q06UDVCPU versions serial number 20081 and prior, update to a version with a serial number later than 20081.
For Mitsubishi Electric Q13UDVCPU versions serial number 20081 and prior, update to a version with a serial number later than 20081.
For Mitsubishi Electric Q26UDVCPU versions serial number 20081 and prior, update to a version with a serial number later than 20081.
For Mitsubishi Electric Q03UDECPU versions serial number 20101 and prior, update to a version with a serial number later than 20101.
For Mitsubishi Electric Q04UDEHCPU versions serial number 20101 and prior, update to a version with a serial number later than 20101.
For Mitsubishi Electric Q06UDEHCPU versions serial number 20101 and prior, update to a version with a serial number later than 20101.
For Mitsubishi Electric Q10UDEHCPU versions serial number 20101 and prior, update to a version with a serial number later than 20101.
For Mitsubishi Electric Q13UDEHCPU versions serial number 20101 and prior, update to a version with a serial number later than 20101.
For Mitsubishi Electric Q20UDEHCPU versions serial number 20101 and prior, update to a version with a serial number later than 20101.
For Mitsubishi Electric Q26UDEHCPU versions serial number 20101 and prior, update to a version with a serial number later than 20101.
For Mitsubishi Electric Q50UDEHCPU versions serial number 20101 and prior, update to a version with a serial number later than 20101.
For Mitsubishi Electric Q100UDEHCPU versions serial number 20101 and prior, update to a version with a serial number later than 20101.
Fix
Resource Exhaustion
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Mitsubishi Electric Q03Udecpu
Mitsubishi Electric Q04Udehcpu
Mitsubishi Electric Q06Udehcpu
Mitsubishi Electric Q100Udehcpu
Mitsubishi Electric Q10Udehcpu
Mitsubishi Electric Q13Udehcpu
Mitsubishi Electric Q20Udehcpu
Mitsubishi Electric Q26Udehcpu
Mitsubishi Electric Q50Udehcpu