PT-2019-4262 · Softnas+1 · Softnas Cloud+1
Published
2019-03-23
·
Updated
2020-08-24
·
CVE-2019-9945
CVSS v3.1
10
Critical
| Vector | AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Name of the Vulnerable Software and Affected Versions
SoftNAS Cloud versions 4.2.0 through 4.2.1
Description
The issue is related to the NGINX default configuration file, which has an inadequate check for a user cookie. This allows an attacker to provide an arbitrary value for the cookie and access the web interface without valid credentials. If SoftNAS StorageCenter ports are exposed directly to the internet, an attacker can gain access to the Webadmin interface, create new users, or execute arbitrary commands with administrative privileges, compromising the platform and data.
Recommendations
For SoftNAS Cloud versions 4.2.0 and 4.2.1, consider restricting access to the Webadmin interface until a patch is available.
As a temporary workaround, avoid exposing SoftNAS StorageCenter ports directly to the internet to minimize the risk of exploitation.
At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Command Injection
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Nginx
Softnas Cloud