PT-2019-9662 · Controlbyweb · X-320M-I
Published
2019-03-17
·
Updated
2019-04-03
·
CVE-2018-18882
CVSS v3.1
5.4
Medium
| Vector | AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N |
Name of the Vulnerable Software and Affected Versions
ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module version 1.05
Description
A stored cross-site scripting issue was found, allowing an authenticated user to inject arbitrary script via the setup.html page in the web interface.
Recommendations
For version 1.05, consider restricting access to the setup.html page in the web interface until a fix is available. As a temporary workaround, avoid using the web interface for sensitive operations until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this issue.
Exploit
Fix
XSS
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
X-320M-I