PT-2020-10456 · Prismview · Prismview System 9+1
Keksec
·
Published
2020-02-10
·
Updated
2021-09-09
·
CVE-2019-20451
CVSS v2.0
10
Critical
| Vector | AV:N/AC:L/Au:N/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
Prismview System 9 version 11.10.17.00
Prismview Player 11 version 13.09.1100
Description
The issue allows for remote code execution through the HTTP API by uploading a specific file, RebootSystem.lnk, and then requesting either "/REBOOTSYSTEM" or "/RESTARTVNC" API endpoints. Authentication is required to exploit this issue, but an XML file containing the necessary credentials can be downloaded, potentially simplifying the exploitation process.
Recommendations
For Prismview System 9 version 11.10.17.00, consider disabling the HTTP API or restricting access to the "/REBOOTSYSTEM" and "/RESTARTVNC" API endpoints until a fix is available.
For Prismview Player 11 version 13.09.1100, restrict access to the HTTP API, specifically to the "/REBOOTSYSTEM" and "/RESTARTVNC" endpoints, to minimize the risk of exploitation.
Exploit
Fix
Unrestricted File Upload
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Prismview Player 11