PT-2020-2434 · Siemens · Scalance S623+3

Published

2020-02-11

·

Updated

2023-04-25

·

CVE-2019-13925

CVSS v2.0

7.8

High

VectorAV:N/AC:L/Au:N/C:N/I:N/A:C
Name of the Vulnerable Software and Affected Versions SCALANCE S602 versions 3.0 through 4.0 SCALANCE S612 versions 3.0 through 4.0 SCALANCE S623 versions 3.0 through 4.0 SCALANCE S627-2M versions 3.0 through 4.0
Description A vulnerability has been identified that could cause a Denial-of-Service condition of the web server. This issue is related to an uncontrolled resource consumption (exhaustion) that can be exploited by sending specially crafted packets to port 443/tcp of affected devices, potentially allowing a remote attacker to cause a service disruption.
Recommendations For SCALANCE S602 versions 3.0 through 4.0, consider restricting access to port 443/tcp as a temporary workaround until a patch is available. For SCALANCE S612 versions 3.0 through 4.0, consider restricting access to port 443/tcp as a temporary workaround until a patch is available. For SCALANCE S623 versions 3.0 through 4.0, consider restricting access to port 443/tcp as a temporary workaround until a patch is available. For SCALANCE S627-2M versions 3.0 through 4.0, consider restricting access to port 443/tcp as a temporary workaround until a patch is available.

Fix

Resource Exhaustion

Weakness Enumeration

Related Identifiers

BDU:2020-02440
CVE-2019-13925

Affected Products

Scalance S602
Scalance S612
Scalance S623