PT-2021-12601 · Bosch · Bosch Monitor Wall

Dhiraj Mishra

·

Published

2021-03-25

·

Updated

2021-03-25

·

CVE-2020-6789

CVSS v3.1

7.8

High

VectorAV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions: Bosch Monitor Wall versions up to and including 10.00.0164
Description: The issue allows an attacker to execute arbitrary code on a victim's system by loading a DLL through an uncontrolled search path element in the Bosch Monitor Wall installer. This can happen if the victim is tricked into placing a malicious DLL in the same directory where the installer is started from.
Recommendations: For versions up to and including 10.00.0164, ensure that no malicious DLLs are placed in the directory where the installer is run to prevent arbitrary code execution. As a temporary workaround, consider restricting the execution of the installer to trusted directories only.

Fix

Uncontrolled Search Path Element

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2020-6789

Affected Products

Bosch Monitor Wall