PT-2021-17429 · Siemens · Sinamics Sl150+8
Published
2021-05-12
·
Updated
2022-10-25
·
CVE-2021-27385
CVSS v3.1
7.5
High
| Vector | AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
Name of the Vulnerable Software and Affected Versions
SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants) versions prior to V15.1 Update 6
SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants) versions prior to V16 Update 4
SIMATIC HMI Comfort Panels V15 4" - 22" (incl. SIPLUS variants) versions prior to V15.1 Update 6
SIMATIC HMI Comfort Panels V16 4" - 22" (incl. SIPLUS variants) versions prior to V16 Update 4
SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F versions prior to V15.1 Update 6
SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F versions prior to V16 Update 4
SIMATIC WinCC Runtime Advanced V15 versions prior to V15.1 Update 6
SIMATIC WinCC Runtime Advanced V16 versions prior to V16 Update 4
SINAMICS GH150 versions prior to not specified
SINAMICS GL150 (with option X30) versions prior to not specified
SINAMICS GM150 (with option X30) versions prior to not specified
SINAMICS SH150 versions prior to not specified
SINAMICS SL150 versions prior to not specified
SINAMICS SM120 versions prior to not specified
SINAMICS SM150 versions prior to not specified
SINAMICS SM150i versions prior to not specified
Description
A remote attacker could send specially crafted packets to the SmartVNC device layout handler on the client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
Recommendations
For SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" (incl. SIPLUS variants), update to version V15.1 Update 6 or later.
For SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" (incl. SIPLUS variants), update to version V16 Update 4 or later.
For SIMATIC HMI Comfort Panels V15 4" - 22" (incl. SIPLUS variants), update to version V15.1 Update 6 or later.
For SIMATIC HMI Comfort Panels V16 4" - 22" (incl. SIPLUS variants), update to version V16 Update 4 or later.
For SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F, update to version V15.1 Update 6 or later.
For SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F, update to version V16 Update 4 or later.
For SIMATIC WinCC Runtime Advanced V15, update to version V15.1 Update 6 or later.
For SIMATIC WinCC Runtime Advanced V16, update to version V16 Update 4 or later.
For SINAMICS products, at the moment, there is no information about a newer version that contains a fix for this vulnerability.
Infinite Loop
Resource Exhaustion
Found an issue in the description? Have something to add? Feel free to write us 👾
Related Identifiers
Affected Products
Simatic Hmi Comfort Outdoor Panels
Simatic Hmi Comfort Panels
Simatic Hmi Ktp Mobile Panels
Simatic Wincc Runtime Advanced
Sinamics Gh150
Sinamics Sl150
Sinamics Sm150
Sinamics Sm120
Sinamics Sm150I