PT-2021-1811 · Cisco · Cisco Dna Center
Prabudas Varadarajan
·
Published
2021-01-20
·
Updated
2025-07-23
·
CVE-2021-1265
CVSS v3.1
7.7
High
| Vector | AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N |
Name of the Vulnerable Software and Affected Versions:
Cisco DNA Center (affected versions not specified)
Description:
The issue is related to the configuration archive functionality, where confidential information is stored unencrypted. This could allow a remote attacker to gain unauthorized access to protected information. The vulnerability is due to configuration archive files being stored in clear text, which can be retrieved by various API calls. An attacker could exploit this by authenticating to the device and executing a series of API calls, potentially retrieving the full unmasked running configurations of managed devices.
Recommendations:
At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Cleartext Storage of Sensitive Information
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Cisco Dna Center