PT-2021-21568 · Siemens · Sinema Remote Connect Server
Published
2021-09-14
·
Updated
2021-09-23
·
CVE-2021-37192
CVSS v3.1
4.3
Medium
| Vector | AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
Name of the Vulnerable Software and Affected Versions
SINEMA Remote Connect Server versions prior to V3.0 SP2
Description
The issue is related to an information disclosure problem that could allow an attacker to retrieve a list of network devices a known user can manage. This could potentially expose sensitive information about the network configuration.
Recommendations
For versions prior to V3.0 SP2, update to V3.0 SP2 or later to resolve the issue. As a temporary workaround, consider restricting access to the affected software to minimize the risk of exploitation.
Fix
Information Disclosure