PT-2021-21854 · Meross · Meross Smart Wi-Fi 2 Way Wall Switch

Gerard Fuguet Morales

·

Published

2021-11-05

·

Updated

2023-11-20

·

CVE-2021-3774

CVSS v3.1

7.4

High

VectorAV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N
Name of the Vulnerable Software and Affected Versions: Meross Smart Wi-Fi 2 Way Wall Switch (MSS550X) versions 3.1.3 and earlier
Description: The issue allows a remote attacker to obtain the Wi-Fi SSID and the password configured by the user from the Meross app via an Http/JSON plain request. This is possible because the device creates an open Wi-Fi Access Point without the required security measures in its initial setup.
Recommendations: For Meross Smart Wi-Fi 2 Way Wall Switch (MSS550X) versions 3.1.3 and earlier, consider disabling the device's Wi-Fi Access Point feature until a secure configuration can be applied. Restrict access to the device's initial setup process to minimize the risk of exploitation. Avoid using the device's default setup until a patch or secure configuration is available. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Cleartext Transmission of Sensitive Information

Weakness Enumeration

Related Identifiers

CVE-2021-3774

Affected Products

Meross Smart Wi-Fi 2 Way Wall Switch