PT-2021-22574 · Philips Healthcare · Philips Healthcare Tasy Electronic Medical Record
Anom
·
Published
2021-08-24
·
Updated
2021-08-31
·
CVE-2021-39376
CVSS v3.1
8.8
High
| Vector | AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
Name of the Vulnerable Software and Affected Versions:
Philips Healthcare Tasy Electronic Medical Record (EMR) version 3.06
Description:
The issue allows SQL injection via the CorCad F2/executaConsultaEspecifico endpoint, specifically through the
IE CORPO ASSIST or CD USUARIO CONVENIO parameters. This could potentially lead to unauthorized access or manipulation of sensitive data.Recommendations:
For version 3.06, consider restricting access to the CorCad F2/executaConsultaEspecifico endpoint until a patch is available. As a temporary workaround, avoid using the
IE CORPO ASSIST or CD USUARIO CONVENIO parameters in the affected endpoint to minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability.Exploit
SQL injection
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Philips Healthcare Tasy Electronic Medical Record