PT-2021-22574 · Philips Healthcare · Philips Healthcare Tasy Electronic Medical Record

Anom

·

Published

2021-08-24

·

Updated

2021-08-31

·

CVE-2021-39376

CVSS v3.1

8.8

High

VectorAV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions: Philips Healthcare Tasy Electronic Medical Record (EMR) version 3.06
Description: The issue allows SQL injection via the CorCad F2/executaConsultaEspecifico endpoint, specifically through the IE CORPO ASSIST or CD USUARIO CONVENIO parameters. This could potentially lead to unauthorized access or manipulation of sensitive data.
Recommendations: For version 3.06, consider restricting access to the CorCad F2/executaConsultaEspecifico endpoint until a patch is available. As a temporary workaround, avoid using the IE CORPO ASSIST or CD USUARIO CONVENIO parameters in the affected endpoint to minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Exploit

SQL injection

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2021-39376

Affected Products

Philips Healthcare Tasy Electronic Medical Record