PT-2021-7770 · Schneider Electric · Evlink Parking+2
Published
2021-07-13
·
Updated
2021-07-27
·
CVE-2021-22722
CVSS v2.0
5.5
Medium
| Vector | AV:N/AC:L/Au:S/C:P/I:P/A:N |
Name of the Vulnerable Software and Affected Versions
EVlink City versions prior to R8 V3.4.0.1
EVlink Parking versions prior to R8 V3.4.0.1
EVlink Smart Wallbox versions prior to R8 V3.4.0.1
Description
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Stored Cross-site Scripting') issue exists that could cause code injection when importing a CSV file or changing station parameters. This allows a remote attacker to inject arbitrary code.
Recommendations
For EVlink City versions prior to R8 V3.4.0.1, update to R8 V3.4.0.1 or later to resolve the issue.
For EVlink Parking versions prior to R8 V3.4.0.1, update to R8 V3.4.0.1 or later to resolve the issue.
For EVlink Smart Wallbox versions prior to R8 V3.4.0.1, update to R8 V3.4.0.1 or later to resolve the issue.
As a temporary workaround, consider restricting the import of CSV files and changing station parameters until a patch is available.
Fix
XSS
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Evlink City
Evlink Parking
Evlink Smart Wallbox