PT-2022-12365 · Siemens · Sicam Pq Analyzer

Published

2022-01-11

·

Updated

2022-01-18

·

CVE-2021-45460

CVSS v3.1

8.1

High

VectorAV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H
Name of the Vulnerable Software and Affected Versions SICAM PQ Analyzer versions prior to V3.18
Description A service is started by an unquoted registry entry, which contains spaces in its path. This allows attackers with write privilege to those directories to potentially plant executables that will run in place of the legitimate process, leading to possible persistence on the system or a denial of service.
Recommendations For versions prior to V3.18, update to version V3.18 or later to resolve the issue. As a temporary workaround, consider restricting write access to the directories containing the unquoted registry entry to minimize the risk of exploitation.

Fix

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2021-45460

Affected Products