PT-2022-1554 · D Link · D-Link Dir-823-Pro

Published

2022-01-24

·

Updated

2022-03-10

·

CVE-2021-46452

CVSS v2.0

10

Critical

VectorAV:N/AC:L/Au:N/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions D-Link DIR-823-Pro version 1.0.2
Description The issue is related to a command injection vulnerability in the SetNetworkTomographySettings function. This vulnerability allows attackers to execute arbitrary commands via the tomography ping address, tomography ping number, tomography ping size, tomography ping timeout, and tomography ping ttl parameters. The vulnerability is caused by insufficient input validation when processing these parameters.
Recommendations For D-Link DIR-823-Pro version 1.0.2, as a temporary workaround, consider disabling the SetNetworkTomographySettings function until a patch is available. Restrict access to the parameters tomography ping address, tomography ping number, tomography ping size, tomography ping timeout, and tomography ping ttl to minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Command Injection

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

BDU:2022-00771
CVE-2021-46452

Affected Products

D-Link Dir-823-Pro