PT-2022-18307 · Siemens · Sinema Remote Connect Server

Published

2022-06-14

·

Updated

2022-06-23

·

CVE-2022-27219

CVSS v2.0

4.3

Medium

VectorAV:N/AC:M/Au:N/C:N/I:P/A:N
Name of the Vulnerable Software and Affected Versions SINEMA Remote Connect Server versions prior to V3.0 SP2
Description A vulnerability has been identified in the SINEMA Remote Connect Server where the affected application is missing general HTTP security headers in the web server configured on port 443. This could aid attackers by making the servers more prone to clickjacking, channel downgrade attacks, and other similar client-based attack vectors.
Recommendations For versions prior to V3.0 SP2, update to V3.0 SP2 or later to resolve the issue. As a temporary workaround, consider configuring the web server to include general HTTP security headers to minimize the risk of exploitation. Restrict access to the web server configured on port 443 to minimize the risk of clickjacking and channel downgrade attacks.

Fix

Clickjacking

Improperly Implemented Security Check for Standard

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2022-27219

Affected Products

Sinema Remote Connect Server