PT-2022-21184 · Siemens · Sinema Remote Connect Server
Published
2022-06-14
·
Updated
2024-07-09
·
CVE-2022-32259
CVSS v3.1
6.5
Medium
| Vector | AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N |
Name of the Vulnerable Software and Affected Versions
SINEMA Remote Connect Server versions prior to V3.1
Description
A vulnerability has been identified where system images for installation or update of the affected application contain unit test scripts with sensitive information. An attacker could gain information about testing architecture and also tamper with test configuration.
Recommendations
For versions prior to V3.1, update to version V3.1 or later to resolve the issue. As a temporary workaround, consider removing or securing the unit test scripts from the system images to prevent information disclosure and tampering. Restrict access to the system images and the affected application to minimize the risk of exploitation.
Fix
Unsafe Debug Access Level
Found an issue in the description? Have something to add? Feel free to write us 👾